Minature Concursores Absorber Linear Dampers TRD-LE
● Parvum et spatium salutaris ad institutionem (videatur CAD drawing pro referat)
● Oleum Type - oleum Silicon
Damping directio est via una - clockwise vel anti - clockwise .
Torque range : 50N-1000N
Minimum vitae tempus - saltem (L) cycles sine oleo ultrices
-
Minature Concursores Absorber Linear Dampers TRD-0855
1.Ictus efficax: Plaga efficax non minus quam 55mm esse debet.
2.Durabilitas Test: Sub condiciones temperaturas normales, damper cyclos 100,000 dis-trahere debet perficere velocitate 26mm/s sine defectu.
3. Force Necessitas: Dum ad processum claudendum tendens, intra primum 55mm ictuum aequilibrium reditum (cum velocitate 26mm/s), vis debilitare debet 5±1N.
4.Temperature Range operans: Effectus debilitans stabilis manere debet intra -30°C ad 60°C sine defectu.
5.Stabilitas operativa: damper nullam stagnationem experiri debet in operatione, nec strepitus abnormes in conventu, nec subitum incrementum in resistentia, lacus, vel defectum.
6.Superficies Quality: Superficies levis sit, sine scalpendo, maculas oleum, et pulvis.
7.Materia Obsequium: Omnes partes parere debent cum ROHS normas et cibum-gradus salutem requiruntur.
8.Corrosio Resistentia: In damper transire debet imbrem 96 horarum neutrum salis test sine signis corrosionis.